Programming Manual
Getting Started
41
PROGRAM
Operation Control
♦
♦♦
♦ Time-out Setting, Good Read Beep Duration ♦
♦♦
♦
F_DEFAULT
Family Code Selection P.C
Parameter Selection Option Code
Scan Input Time-out
SS
SS
SS
SS
SS
MS
100 msec.
200 msec.
300 msec.
400 msec.
500 msec.
600 msec.
700 msec.
800 msec.
900 msec.
User define: 1-99 sec.
0
1
2
3
4
5
6
7
8
9, (2digits)
Hands Free Time-out
SS
SS
SS
SS
SS
Short
Medium
Long
Extremely long
Disable
0
1
2
3
4
Good Read Duration
SS
SS
SS
SS
SS
Short
Medium
Long
Extremely long
Extremely short
0
1
2
3
4
Time Delay to Low Power Mode
SS
SS
SS
SS
SS
SS
1 sec
3 secs
5 secs
7 secs
9 secs
Immediate
0
1
2
3
4
5
The Scan Input Time-out is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The engine keeps the light source on till
the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.
The Presentation Mode and Force Mode are referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode when you
activate the trigger. You can remain the engine in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any trigger
operation), the imager will revert to the original hands free mode.
The Time Delay to Low Power Mode sets the time for engine to enter low power mode after any scanning activity. This setting is only available for the engine is in low
power mode.